国产精品天干天干,亚洲毛片在线,日韩gay小鲜肉啪啪18禁,女同Gay自慰喷水

歡迎光臨散文網(wǎng) 會員登陸 & 注冊

[VPLEX]開關機步驟

2023-02-17 09:42 作者:墨小胎  | 我要投稿

開關機的基本順序:

開機: 光纖交換機――存儲設備――VPLEX――主機系統(tǒng)

關機: 主機系統(tǒng)――VPLEX ――存儲設備――光纖交換機

?

關機操作

1.關閉cluster-1上的軟件

1.鍵入以下命令關閉cluster1中的軟件:

VPlexcli:> cluster shutdown --cluster cluster-1

Warning: Shutting down a VPlex cluster may cause data unavailability.? Please refer to the VPlex documentation for the

recommended procedure for shutting down a cluster. To show that you understand the impact, enter 'shutdown': shutdown

?

You have chosen to shutdown 'cluster-1'.? To confirm, enter 'cluster-1': cluster-1??

?

Status??? Description

--------? -----------------

Started.? Shutdown started.

?

說明:系統(tǒng)需要大約3-5分鐘才能關閉.

2.顯示集群狀態(tài)的命令如下,在輸出中,確認集群1的操作狀態(tài)沒有運行。

VPlexcli:/> cluster status

Cluster cluster-1

??????? operational-status:??????? not-running

??????? transitioning-indications:

??????? transitioning-progress:???

??????? health-state:????????????? unknown

??????? health-indications:???????

??????? local-com:???????????????? failed to validate local-com: Firmware command error.

communication error recently.

?

2.關閉集群-1上的控制器和可選的COM開關

1.輸入exit,退出vplexcli模式,輸入以下命令關閉director 1-1-1-A:

ssh -l root 128.221.252.35

shutdown –P “now”

輸出如下:

director-1-1-a:~ # shutdown -P "now"

Broadcast message from root (pts/0) (Fri Nov 18 20:04:33 2011):

The system is going down to maintenance mode NOW!

重復步驟關閉集群其他控制器


ping –b 128.221.252.35

注意:一個控制器可能需要4分鐘的時間來完全關閉。

輸出如下:

PING 128.221.252.35 (128.221.252.35) 56(84) bytes of data.

From 128.221.252.33 icmp_seq=1 Destination Host Unreachable

From 128.221.252.33 icmp_seq=2 Destination Host Unreachable

重復ping其他控制器,確認關閉

2.如果集群只有一個引擎,則跳到任務3:“關閉管理服務器”。

3.如果集群有多個引擎,請按照以下步驟關閉Fibre Channel COM交換機:

輸入以下命令連接到交換機A:

telnet 128.221.252.34

使用用戶名service登錄。

在交換機的命令行,鍵入以下命令關閉開關:

sysshutdown

輸出如下:

--------------------------------------------------------------

FC-Switch-A:service> sysshutdown

This command will shutdown the operating systems on your switch.

You are required to power-cycle the switch in order to restore operation.

Are you sure you want to shutdown the switch [y/n]?y

輸入y,在提示處按回車鍵。

Broadcast message from root (pts/0) Fri Nov 18 20:09:11 2011...

?

The system is going down for system halt NOW !!

FC-Switch-A:service> Connection closed by foreign host.

輸入exit命令終止切換會話,輸入以下命令到ping開關A:

ping –b 128.221.252.34

使用想通方法關閉交換機B,IP地址更換為128.221.253.34

3.關閉cluster-1的管理服務器

VPLEX VS2

鍵入以下命令關閉cluster-1上的管理服務器:

sudo /sbin/shutdown 0

輸出如下:

Broadcast message from root (pts/1) (Tue Feb 8 18:12:30 2010):

The system is going down to maintenance mode NOW!

?

VPLEX VS6

關閉MMCS-B

使用ssh登陸到MMCS-B

ssh service@128.221.253.33

執(zhí)行關機命令

sudo /sbin/shutdown 0

輸出如下

Broadcast message from root (pts/1) (Tue Feb 8 18:12:30 2010):
The system is going down to maintenance mode NOW!

然后以輸入關閉命令關閉MMCS-A

sudo /sbin/shutdown 0

輸出如下

Broadcast message from root (pts/1) (Tue Feb 8 18:12:30 2010):
The system is going down to maintenance mode NOW!

?

4移除電源線

將所連接電源線全部移除

?

開機操作

? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

1.?????? 檢查所有供電線路聯(lián)接是否正常,是否有松動或改動并改正。

2.?????? 打開vplex mamagement server 的電源開關。

3.?????? 打開機柜最底部兩個vplex電池的開關,完成開機。